P2
Nordic Hot Tubs
Pump 2 Circuit Failure
Display shows P2 ERR or P2 FAIL; pump 2 does not run or behaves erratically.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Seized pump 2 motor, Loose pump 2 connector at control pack, Failed pump 2 relay, Incorrect dip switch configuration for second pump
How to Fix / Troubleshooting
Safety first: Disconnect power at the GFCI breaker before servicing pump 2 or the control pack.
- Step 1 – Operate pump 2: Press the JETS 2 button and observe. Humming, no start, or breaker trip indicates motor or wiring issues.
- Step 2 – Inspect connections: With power off, verify the pump 2 plug is fully seated on the control board and that the cord is undamaged.
- Step 3 – Check motor shaft: Attempt to rotate the pump 2 motor shaft by hand with power off. If it is stiff or frozen, the motor is likely seized.
- Step 4 – Verify configuration: On some Nordic models, dip switches on the control board must be set correctly for a second pump. Confirm settings match the spa’s configuration (refer to wiring diagram inside the control box cover).
- Step 5 – Replace pump 2: If the motor is faulty, replace the pump 2 assembly with a Nordic-approved unit.
- Step 6 – Replace control board if needed: If the pump is good but never powered, the pump 2 relay or board may be defective.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Pump 2 Assembly
Check Price on Amazon