dE
Passion Spas
Dip Switch / Configuration Error
Display shows dE or DE; spa may shut down or limit functions.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect dip switch settings on control pack, Wrong software configuration for spa model, Recently replaced control pack not programmed for Passion Spas layout
How to Fix / Troubleshooting
Safety first: Turn off power at the main breaker before opening the control pack.
- Check dip switch settings: Compare the dip switch positions on the control board with the wiring diagram label inside the control pack cover or Passion Spas documentation for your exact model.
- Correct configuration: Set the switches to match the number of pumps, heater size, and voltage configuration of your spa.
- Power cycle: After adjusting, close the pack, restore power, and verify that dE clears.
If you recently installed a new control pack, ensure it is the correct model and software revision for your Passion Spas hot tub.
Advertisements
Repair Difficulty
Hard
4/5