ICE
RivieraPool Freeze Protection Mode

Display shows ICE and pumps run periodically even when spa is not in use.

Advertisements

Possible Causes

Water temperature near freezing, Ambient temperature sensor detecting low temperature, Faulty sensor reading too low

How to Fix / Troubleshooting

Safety: Do not shut off power to the spa in freezing weather; this can cause plumbing damage.

  • Confirm actual water temperature: Use a separate thermometer to verify water temperature. If near freezing, ICE is functioning correctly.
  • Keep cover on: Ensure the RivieraPool cover is in good condition and properly latched to retain heat.
  • Check sensors: If ICE appears when water is warm, inspect the temperature sensor and any ambient/freeze sensor for damage or loose connections.
  • Replace faulty sensor: Install a new RivieraPool temperature or freeze sensor if readings are inaccurate.
  • Monitor operation: After sensor replacement, observe that ICE only appears in genuinely cold conditions.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

RivieraPool freeze/temperature sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements