Saratoga Spas No Heat Without Error Code

Spa does not heat, temperature stays well below set point, but pumps and jets work normally and no heater error code is displayed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Heater element partially open or weak, Miswired heater after previous repair, Temperature set too low or in economy mode, Faulty temperature sensor reading high

How to Fix / Troubleshooting

Safety: Turn off power before accessing heater wiring.

  • Confirm settings: Verify the set temperature is higher than current water temperature and that the spa is in STANDARD/READY mode, not ECON/SLP.
  • Check heat indicator: On many Saratoga Spas, a heat icon or LED indicates when the heater should be on. If it never appears, the control logic may not be calling for heat.
  • Inspect heater wiring: Ensure both heater leads are securely attached to the control pack terminals.
  • Test heater element: With power OFF and wires removed, measure resistance across the heater. Compare to specifications; a very high or infinite reading indicates failure.

If the heater tests good but does not energize, the control board or sensor inputs should be tested by a technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Heater Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements