Sundance Spas
Air Control Valve Failure
Air control knobs are difficult to turn or do not change jet air flow.
Advertisements
Possible Causes
Worn internal air valve components, Scale or debris buildup, Broken stem or handle, Disconnected air line
How to Fix / Troubleshooting
Safety first: Turn off pumps before removing any air control components.
- 1. Test function: With jets running, turn the air control knobs fully open and closed to see if there is any change in air flow.
- 2. Remove knob and cap: Unscrew or pull off the knob and cap to access the internal valve.
- 3. Inspect and clean: Remove debris and scale from the valve body. Check for broken parts.
- 4. Replace valve: If the internal mechanism is damaged, replace the air control valve with a Sundance-compatible part.
- When to call a technician: If the air line has come loose below the shell, access may require cabinet and insulation removal.