PF
Sundance Spas Power Failure / Power Fluctuation Detected

Display shows PF or PFL; spa may shut down or reset unexpectedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Recent power outage or brownout, Loose main power connections in control box, Undersized or long electrical run causing voltage drop, Failing GFCI breaker

How to Fix / Troubleshooting

Safety first: Turn off power at the main breaker before tightening any electrical connections. Only work on electrical components if you are qualified.

  • 1. Confirm utility power stability: Check if other appliances in the home experienced outages or flickering lights.
  • 2. Inspect main lugs: With power OFF, open the Sundance control box and inspect the main power lugs for looseness, discoloration, or heat damage. Tighten only if you are trained to do so.
  • 3. Check GFCI breaker: Test the GFCI by pressing the TEST and RESET buttons. If it trips frequently without cause, it may be failing.
  • 4. Monitor for recurrence: Restore power and observe if PF returns. If it does, note the conditions (pump speed, heater on, etc.).
  • When to call a technician/electrician: Persistent PF errors may indicate wiring issues, undersized conductors, or a failing breaker and should be evaluated by a licensed electrician or spa technician.
Advertisements

Repair Difficulty

Hard 4/5