P1
Sunrise Spas Pump 1 Drive or Overcurrent Fault

Display shows P1 ERROR or Pump 1 will not run when commanded

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Seized Pump 1 motor, Failed start/run capacitor on Pump 1, Loose wiring at Pump 1 terminals, Control board triac/relay failure for Pump 1

How to Fix / Troubleshooting

Safety first: Turn off power at the GFCI before touching the pump or wiring.

  • Check for obstructions: With power off, try to rotate the Pump 1 motor shaft (at the rear fan or using a screwdriver in the shaft slot) to see if it is seized.
  • Inspect wiring: Verify that Pump 1 wires are secure at both the control pack and the pump junction box.
  • Capacitor check: Many Sunrise Spas jet pumps use an external capacitor. Look for bulging or leaking. Replace if suspect.
  • Test operation: Restore power and try low and high speeds. If the pump hums but does not start, shut off power and replace the pump or capacitor.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Jet Pump 1
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements