PF
Sunrise Spas Power Fault / Line Voltage Error

Display shows PF or PFL, spa randomly shuts off or reboots

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect wiring at GFCI breaker, Loose line or neutral connections in control pack, Low supply voltage, Shared circuit with high-load devices

How to Fix / Troubleshooting

Safety first: Turn off power at the main panel before opening any electrical boxes. If you are not comfortable with electrical work, contact a licensed electrician.

  • Verify dedicated circuit: Sunrise Spas hot tubs must be on a dedicated GFCI circuit of the correct amperage. Ensure no other loads share this circuit.
  • Check wiring connections: With power off, open the control pack and confirm that L1, L2, and Neutral (if used) are securely tightened to the terminal block according to the Sunrise Spas wiring diagram.
  • Inspect GFCI breaker: Look for signs of overheating or loose connections at the breaker. Tighten as needed.
  • Measure voltage (advanced): Using a multimeter, verify that line voltage at the spa matches the nameplate (e.g., 240V). Low or fluctuating voltage can trigger PF errors.
Advertisements

Repair Difficulty

Hard 4/5