Sunrise Spas
No Power / Dead Spa
Spa will not power on at all, no lights or display
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped GFCI breaker, Loose main power connections at control pack, Blown internal fuse on control board, Failed Sunrise Spas control pack
How to Fix / Troubleshooting
Safety first: Treat all wiring as live until verified otherwise. Turn off the main breaker before opening panels.
- Check GFCI: Locate the spa’s GFCI breaker and ensure it is in the ON position. Reset if tripped. If it trips immediately, there may be a short.
- Inspect disconnect: If there is an outdoor disconnect box, verify that it is on and connections are tight.
- Open equipment bay: With power off, remove the front panel and check that the main power wires are securely attached to the control pack terminals.
- Internal fuses: Many Sunrise Spas packs have one or more fuses on the board. Inspect and replace only with identical ratings if blown.
- Persistent failure: If power is present at the pack but no display, the control pack may need replacement by a technician.
Advertisements
Repair Difficulty
Hard
4/5
Advertisements