Tuff Spas
No Power / Dead Spa
Spa will not power on at all; topside display is blank and no pumps run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped or failed GFCI breaker, Loose or incorrect wiring to Tuff Spas control pack, Blown internal fuse on control board, Failed control pack power supply
How to Fix / Troubleshooting
Safety: Working with 240V power is hazardous. If you are not experienced, contact a licensed electrician or spa technician.
- Step 1 – Check GFCI breaker: Locate the spa’s dedicated GFCI breaker. If it is tripped, reset it fully OFF then ON. If it trips immediately, do not keep resetting—there may be a short.
- Step 2 – Verify service disconnect: Ensure any outdoor disconnect box feeding the Tuff Spas unit is in the ON position.
- Step 3 – Inspect internal fuses: With power off and locked out, remove the control pack cover and check for glass or blade fuses on the board. Replace only with identical ratings.
- Step 4 – Look for burn marks: Inspect the control board for burned components or melted connectors, which indicate a failed control pack.
If the spa remains dead after breaker and fuse checks, the control pack or incoming wiring likely needs professional diagnosis and repair.
Advertisements
Repair Difficulty
Professional Required
5/5