DR
USSPA
Dry Fire Protection / Low Water in Heater
Display shows DR and heater is disabled; spa may think it is running dry.
Advertisements
Possible Causes
Airlock in heater tube, Very low water level in spa, Blocked suction or closed valves, Recently refilled spa not properly bled
How to Fix / Troubleshooting
Safety first: Turn OFF power at the breaker before opening unions or removing filters.
- Check water level:
- Ensure the spa is filled to the recommended level, typically above all jets and skimmers.
- Open all valves:
- Verify that all slice valves around the pumps and heater are fully open.
- Bleed air from heater and pumps:
- Loosen the unions on the circulation pump and heater until water flows steadily, then retighten.
- Clean filters:
- Remove and rinse filters to ensure they are not restricting flow.
- Reset and test:
- Restore power and observe if DR clears.
- If DR persists, there may be a sensor or control issue requiring professional diagnosis.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Heater Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements