F5
USSPA Pump 1 Control / Relay Fault

Control panel shows F5 and jets may not respond correctly; pump speeds may be locked or unavailable.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed pump 1 relay on main control board, Shorted or seized primary jet pump motor, Loose pump 1 wiring at control pack, Overcurrent condition tripping internal protection

How to Fix / Troubleshooting

Safety first: Turn OFF power at the breaker before touching pumps or control wiring.

  • Check pump 1 operation:
    • With power ON (before opening anything), try to start Pump 1 from the topside.
    • Listen for humming, clicking, or no response. Then turn power OFF again.
  • Inspect pump 1 connections:
    • Open the equipment bay and locate Pump 1 (usually the largest jet pump).
    • Verify that the pump power cable is firmly connected to the Pump 1 output on the USSPA control pack.
    • Check for burned connectors or melted insulation.
  • Check pump motor for seizure:
    • With power OFF, try to rotate the pump shaft or impeller (via rear fan or coupling) by hand. It should turn smoothly.
    • If it is locked or very stiff, the pump motor is likely seized and must be replaced.
  • Inspect control board:
    • Open the control box and locate the Pump 1 relay.
    • Look for burn marks, cracked solder joints, or signs of overheating.
  • Corrective actions:
    • If the pump is seized or shorted, replace the complete USSPA-compatible jet pump assembly.
    • If the pump tests good but F5 persists, replace the main control board or have the relay professionally replaced.
  • Final test:
    • After reassembly, restore power and test Pump 1 at all speeds.
    • Confirm that F5 no longer appears and that the pump runs smoothly without tripping breakers.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Jet Pump 1
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements