FLO
USSPA
Insufficient Water Flow / Flow Switch Open
Display shows FLO and heater will not turn on; circulation appears weak or absent.
Advertisements
Possible Causes
Dirty or clogged filters, Airlock in circulation pump or heater, Stuck or failed flow switch in plumbing, Blocked suction or return lines
How to Fix / Troubleshooting
Safety first: Turn OFF power at the breaker before removing filters or opening any unions.
- Clean filters:
- Remove all filter cartridges and rinse thoroughly.
- Temporarily run the spa without filters to see if FLO clears (do not leave filters out long-term).
- Bleed air from system:
- Loosen the union on the circulation pump until water seeps out, then retighten.
- Do the same on the heater unions if accessible.
- Check water level and valves:
- Ensure water level is adequate and all slice valves are fully open.
- Inspect flow switch:
- Locate the flow switch in the plumbing near the heater (often a tee with two wires).
- Check for kinks or blockages around it.
- With power OFF, disconnect and reconnect the flow switch wires to ensure a good connection.
- Replace flow switch if necessary:
- If good flow is present but FLO persists, the flow switch may be stuck or failed.
- Replace with a USSPA-compatible flow switch, ensuring correct orientation (arrow in direction of flow).
Advertisements
Repair Difficulty
Easy
2/5