Spa water is cloudy, foamy, or has a strong odor despite filtration.
Advertisements
Possible Causes
Dirty or worn filter cartridges, Insufficient sanitizer levels, Imbalanced pH and alkalinity, Biofilm buildup in plumbing lines
How to Fix / Troubleshooting
Safety first: Avoid using the spa until water chemistry is corrected.
- Clean or replace filters:
- Remove filters and soak in a filter cleaner solution, then rinse thoroughly.
- Replace filters if they are more than 1–2 years old or show signs of collapse.
- Balance water chemistry:
- Test pH, alkalinity, and sanitizer levels with a reliable test kit.
- Adjust to USSPA-recommended ranges.
- Shock the spa:
- Use a non-chlorine or chlorine shock to oxidize contaminants.
- Flush plumbing if persistent:
- Use a spa pipe cleaner product before the next drain/refill to remove biofilm from USSPA plumbing lines.