F5
Wellis
Pump 2 Sensor / Current Fault
F5 displayed, secondary pump will not run or trips immediately
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Seized or blocked jet pump 2, Incorrect pump amperage installed, Loose or burned connector at control pack, Faulty control board output for Pump 2
How to Fix / Troubleshooting
Safety first: Shut off power at the breaker before touching any pump or wiring.
- 1. Confirm which pump is affected:
- Use the topside controls to identify Pump 2 (often a booster or lounge pump).
- Note if it hums, clicks, or does nothing when commanded on.
- 2. Inspect Pump 2 physically:
- Open the equipment bay and locate Pump 2.
- Check that slice valves are open and that there are no kinks in the suction or return hoses.
- Try to spin the motor shaft by hand (power OFF). If it is stiff or locked, the pump is likely bad.
- 3. Check electrical connections:
- Verify the pump plug is fully seated in the Pump 2 socket on the control pack.
- Look for heat damage or corrosion on the connector.
- 4. Compare pump rating:
- Confirm the installed pump matches the amperage and voltage specified by Wellis for your model.
- Oversized pumps can overload the control board and trigger F5.
- 5. Test with pump disconnected (technician):
- With power OFF, unplug Pump 2 from the control pack.
- Restore power and see if F5 clears. If it does, replace Pump 2.
- If F5 remains, the control board may need replacement.