AEG Keypad / Button Failure

Dehumidifier display works but buttons do not respond

Advertisements

Possible Causes

Worn or damaged membrane keypad, Loose control panel connector, Liquid ingress into control panel

How to Fix / Troubleshooting

Safety: Unplug the unit before opening the control panel.

  • Check for child lock: Ensure no control lock function is active (see LC entry).
  • Inspect control panel: Remove the top/front cover and look for signs of moisture or corrosion on the control panel PCB.
  • Reseat connectors: Disconnect and reconnect the ribbon cable between the control panel and main PCB.
  • Dry panel: If there are signs of moisture, allow the panel to dry completely. Do not use heat guns directly on electronics.
  • Replace keypad/board: If specific buttons remain nonfunctional, replace the control panel PCB or membrane keypad assembly.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Control Panel PCB
Check Price on Amazon

We may earn a commission from links on this page.