AEG Refrigeration System Underperformance

Dehumidifier runs but does not collect water, room remains humid

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge, Severely dirty evaporator or condenser coils, Faulty compressor, Blocked capillary tube or expansion device

How to Fix / Troubleshooting

Safety: Unplug the unit before cleaning or inspection. Do not open the sealed refrigeration circuit.

  • Check operating conditions: Ensure room temperature is within the specified range and doors/windows are closed to reduce moisture load.
  • Clean filter and coils: Remove and wash the air filter. Carefully brush and vacuum dust from both evaporator and condenser coils.
  • Check for frost pattern: Run the unit for 20–30 minutes and inspect the evaporator. Uniform coolness or light frost is normal; no cooling or only a small iced section suggests low refrigerant or a restriction.
  • Listen to compressor: Confirm the compressor is running (steady hum) and not cycling rapidly. If the compressor is silent while the fan runs, see compressor fault entries.
  • Professional diagnosis: If cleaning and basic checks do not restore water collection, a technician must test for refrigerant leaks or a failing compressor.
Advertisements

Repair Difficulty

Hard 4/5