AEG
Humidity Reading Inaccuracy
Dehumidifier shows incorrect humidity compared to a separate hygrometer
Advertisements
Possible Causes
Aged or drifted humidity sensor, Sensor obstructed by dust, Sensor placed too close to exhaust air, Firmware calibration offset
How to Fix / Troubleshooting
Safety: Unplug before accessing the sensor.
- Verify with multiple meters: Compare readings with at least one reliable external hygrometer.
- Clean sensor: Gently clean the humidity sensor vent area with a soft brush or compressed air.
- Check location: Ensure the sensor is in the intake airflow, not directly in the warm, dry exhaust stream.
- Sensor replacement: If readings remain significantly off, replace the humidity sensor assembly.
- Adjust setpoint: Compensate minor offsets by adjusting the target humidity a few percent up or down.