EC
AEG
Refrigerant Leak / Cooling System Error
Dehumidifier shows EC and stops dehumidifying
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Refrigerant leak in evaporator or condenser, Blocked capillary tube, Severely reduced compressor performance, Faulty temperature sensor misreading system
How to Fix / Troubleshooting
Safety: Refrigerant systems are not DIY. Do not attempt to cut or open copper lines.
- Visual inspection: Look for oily residue on the evaporator, condenser, or piping, which can indicate a refrigerant leak.
- Check coil temperatures: After running for 10–15 minutes, the evaporator should be cool and the condenser warm. If both are near room temperature, the system may be low on refrigerant.
- Clean coils and filter: Ensure the air filter and coils are clean to rule out airflow issues.
- Sensor check: Verify that the evaporator NTC sensor is correctly attached and functioning.
- Professional service: If EC persists, contact an authorized AEG service technician to locate and repair leaks and recharge the system.
Advertisements
Repair Difficulty
Professional Required
5/5