AIRCARE
Premature Shutoff Due to Faulty Humidity Sensing or Overheat Protection
Humidifier turns on but shuts off after a few seconds or minutes without reaching the set humidity.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Humidity sensor reading incorrectly high, Unit placed too close to humidity source (like a vent), Blocked air intake causing motor overheating, Faulty thermal cutoff on motor
How to Fix / Troubleshooting
Safety first: Unplug the unit before moving or opening it.
- Step 1 – Relocate the unit: Move the humidifier away from heat registers, bathrooms, or kitchens where humidity spikes quickly and can fool the sensor.
- Step 2 – Clean air path: Vacuum the intake and outlet grilles. Ensure nothing is blocking airflow around the unit.
- Step 3 – Bypass auto mode: Set the humidifier to continuous or manual mode (if available) and observe whether it still shuts off quickly. If it runs normally, the humidity sensor may be faulty or poorly located.
- Step 4 – Inspect humidity sensor: Access the control area and locate the RH sensor. Ensure it is not directly in the path of the outlet air and that its connector is secure.
- Step 5 – Replace sensor or motor protection (advanced): If the motor is hot to the touch and the unit shuts down, the thermal protector may be tripping due to a failing motor. Replace the fan motor assembly. If the shutdown is tied to false high humidity readings, replace the RH sensor.
After repair, verify that the unit runs steadily and cycles only when the room actually reaches the set humidity.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Humidity Sensor or Fan Motor Assembly