Aprilaire Improper Condensate Pump Integration

Aprilaire dehumidifier does not drain properly when connected to a condensate pump

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Pump reservoir full or failed, Discharge line from pump blocked, Dehumidifier drain line not sloped to pump, Pump safety switch wired incorrectly to dehumidifier

How to Fix / Troubleshooting

Safety first: Unplug both the dehumidifier and condensate pump before servicing. Water and electricity are a hazardous combination.

  • Check pump operation: Manually fill the pump reservoir with water and plug it in. Verify it pumps out water and shuts off properly.
  • Inspect discharge line: Ensure the pump’s discharge tubing is not kinked, blocked, or run too high above the pump’s rated lift.
  • Verify drain slope: Confirm the dehumidifier’s drain line slopes downward into the pump reservoir with no upward loops.
  • Check safety switch wiring: If the pump has an overflow safety switch wired to the dehumidifier, verify it is wired to the correct low-voltage interlock terminals so that an overflow will shut off the dehumidifier.
  • Replace pump if failed: If the pump does not run or evacuate water, replace the condensate pump with a compatible model.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condensate Pump (external to Aprilaire unit)
Check Price on Amazon