Aprilaire
Compressor Start Circuit Failure
Aprilaire dehumidifier fan runs but compressor never starts
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed compressor run capacitor, Open compressor winding, Faulty compressor relay on control board, Low line voltage
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker and verify power is off before opening the electrical compartment. Capacitors can hold a charge; discharge safely.
- Check line voltage: Measure voltage at the dehumidifier input terminals. Ensure it matches the nameplate rating.
- Inspect capacitor: Locate the compressor run capacitor. Look for bulging, leaking, or burned terminals. Replace the Aprilaire compressor run capacitor if any damage is visible.
- Test capacitor: Use a capacitance meter to verify the µF value is within ±10% of the rating. Replace if out of range.
- Check compressor windings: With power off and wires removed, measure resistance between compressor terminals (C-R, C-S, R-S). Open circuits indicate a failed compressor.
- Replace control relay/board: If the compressor and capacitor test good but the board never sends power to the compressor, replace the Aprilaire dehumidifier main control board.