Aprilaire
Condensation on Bypass Duct
Aprilaire humidifier bypass duct is sweating or dripping water
Advertisements
Possible Causes
Uninsulated bypass duct in cold space, Excess humidity in duct, Cold air contacting warm moist air, Poor duct sealing
How to Fix / Troubleshooting
Safety first: Turn off furnace power before working around ductwork.
- Insulate duct: Wrap the bypass duct with appropriate duct insulation to prevent condensation on the exterior.
- Seal joints: Use foil tape or mastic to seal all duct joints and connections to prevent moist air leakage.
- Check damper position: Ensure the bypass damper is closed during cooling season to reduce moisture-laden air in the duct.
- Control humidity: If indoor humidity is excessively high, adjust the humidifier setpoint or use an Aprilaire dehumidifier to reduce overall moisture.
Advertisements
Repair Difficulty
Easy
2/5