Aprilaire
Humidistat Stuck Closed or Miscalibrated
Aprilaire humidifier continues running even when humidity setpoint is reached
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Mechanical humidistat contacts welded closed, Digital control miscalibrated, Shorted control wiring, Outdoor sensor misreading causing over-humidification
How to Fix / Troubleshooting
Safety first: Turn off furnace power before working on control wiring.
- Check actual humidity: Use a separate hygrometer to verify room humidity. If it is significantly higher than the setpoint, the control is not regulating correctly.
- Inspect wiring: Ensure the humidistat/control wires are not shorted together. Remove the wires from the humidistat and see if the humidifier stops; if it continues, the short is elsewhere.
- Test humidistat: For mechanical models, use a multimeter to check continuity across the control terminals while adjusting the dial. It should open when set below room humidity.
- Replace control: If the humidistat remains closed or a digital control does not respond to setpoint changes, replace the Aprilaire humidistat/digital control.
- Verify outdoor sensor: For automatic controls, ensure the outdoor sensor is reading correctly; a failed sensor can cause over-humidification.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Aprilaire Humidistat / Digital Humidifier Control
Check Price on Amazon