E6
Aprilaire Communication Error Between Dehumidifier and Remote Wall Control

Aprilaire dehumidifier displays E6 and will not respond to wall control

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted communication cable, Miswired A/B or R/C terminals, Excessive cable length or wrong cable type, Failed wall control or main control board

How to Fix / Troubleshooting

Safety first: Turn off power to the dehumidifier and wall control circuit before working on wiring.

  • Inspect cable: Trace the low-voltage cable from the dehumidifier to the Aprilaire wall control. Look for staples through the cable, tight bends, or damage.
  • Verify wiring order: At both ends, confirm that terminals (e.g., A, B, R, C) are wired to the same letters. Re-terminate any loose or crossed wires.
  • Check for shorts: Remove the cable from both devices and test each conductor to all others with a multimeter. There should be no continuity between conductors.
  • Test with short jumper: Temporarily connect the wall control to the dehumidifier with a short piece of known-good thermostat wire. If E6 clears, the original cable is defective and should be replaced with 18/2 or 18/4 thermostat cable per Aprilaire specs.
  • Swap control if needed: If a known-good cable does not resolve E6, either the Aprilaire wall control or the dehumidifier main control board may be faulty and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Aprilaire Dehumidifier Wall Control
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements