E7
Aprilaire Water Panel / Service Interval Lockout (Some Models)

Aprilaire digital humidifier control displays E7 and humidifier runs erratically or not at all

Advertisements

Possible Causes

Exceeded service hours for water panel, Control set to lockout after pad life, Water panel extremely clogged, Flow-through tray blocked causing overflow

How to Fix / Troubleshooting

Safety first: Turn off power to the furnace and shut off the humidifier water supply.

  • Inspect water panel: Open the Aprilaire humidifier cover and remove the water panel (evaporative pad). Check for heavy mineral buildup, crumbling media, or algae.
  • Clean or replace: Replace the Aprilaire water panel (evaporative pad) with the correct model (e.g., 10, 12, 35, 45, 56, etc., depending on unit). Do not attempt to chip off heavy scale; replacement is recommended.
  • Clean distribution tray: Remove the top distribution tray and rinse out mineral deposits from the slots and holes so water can flow evenly.
  • Reset service indicator: Follow the control’s instructions (often holding the reset or up/down buttons for several seconds) to clear the E7/service reminder.
  • Restore operation: Turn water and power back on, then call for humidity and verify even water flow over the new panel.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Aprilaire Water Panel (Evaporative Pad)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements