F1
Aprilaire
High Refrigerant Pressure / High Head Pressure Fault
Aprilaire dehumidifier displays F1 and will not start compressor
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked condenser coil, Failed condenser fan motor, Overcharged refrigerant system, High ambient temperature around unit, Restricted discharge duct
How to Fix / Troubleshooting
Safety first: Disconnect power before servicing. Refrigerant work must be performed by a licensed HVAC technician.
- Check airflow around unit: Ensure there is adequate clearance around the dehumidifier and that discharge and intake are not blocked.
- Inspect condenser coil: With power off, remove the panel and inspect the warm (condenser) coil for dust and lint. Clean with a soft brush and vacuum or coil cleaner.
- Verify fan operation: Restore power briefly and observe if the condenser fan runs when the compressor starts. If the fan does not run, replace the Aprilaire condenser fan motor or capacitor as applicable.
- Check ducting: If ducted, verify that the supply duct is not collapsed or undersized, which can trap heat.
- Professional service: If airflow and fan are correct but F1 persists, contact an HVAC technician to check refrigerant pressures and correct any charge or restriction issues.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Aprilaire Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements