HI
Aprilaire High Humidity Indication / Sensor at Upper Limit

Aprilaire dehumidifier display shows HI and runs continuously

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Actual humidity above 80–90%, Failed humidity sensor reading high, Sensor exposed to liquid water or condensation, Control setpoint too low

How to Fix / Troubleshooting

Safety first: Unplug the unit before accessing internal sensors.

  • Confirm humidity: Use a separate hygrometer to verify actual room humidity. If humidity is truly very high, allow the unit to run and improve ventilation in the space.
  • Check setpoint: Ensure the humidity setpoint is reasonable (e.g., 45–55%). Extremely low setpoints can cause long run times.
  • Inspect humidity sensor: Locate the RH sensor near the air intake. Ensure it is not wet or covered in dust. If it has been exposed to liquid water, allow it to dry completely.
  • Replace sensor if faulty: If the external hygrometer shows normal humidity but the unit still reads HI, replace the Aprilaire humidity sensor or control board assembly that contains it.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Aprilaire Humidity Sensor
Check Price on Amazon