LO
Aprilaire
Low Ambient Temperature Lockout
Aprilaire dehumidifier display shows LO and unit does not dehumidify
Advertisements
Possible Causes
Space temperature below operating range, Faulty ambient temperature sensor, Unit installed in unconditioned space outside spec
How to Fix / Troubleshooting
Safety first: No internal work is required for basic checks; unplug before accessing sensors.
- Measure room temperature: Use a thermometer to confirm the space temperature. If below the unit’s minimum (often around 50°F/10°C), relocate the dehumidifier or warm the space.
- Check sensor location: Ensure the ambient/return temperature sensor is located where it senses actual room air, not against a cold exterior surface.
- Test sensor: With power off, measure resistance of the ambient sensor and compare to the thermistor chart. Replace the Aprilaire ambient temperature sensor if readings are incorrect.
- Restore power: After correcting temperature or replacing the sensor, restore power and verify LO clears.