Ariston No Power / Dead Unit

Dehumidifier does not power on at all; no lights or display

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal fuse on main PCB, Faulty power cord or plug, Failed main control board, Defective power switch or keypad

How to Fix / Troubleshooting

Safety: Ensure the outlet is safe and not overloaded. Unplug the unit before opening any covers.

Steps to troubleshoot no power:

  • 1. Check outlet and breaker: Test the outlet with another appliance. Reset any tripped breakers.
  • 2. Inspect power cord: Look for cuts, burns, or kinks. If damaged, replace the power cord assembly.
  • 3. Access main PCB: Remove the rear or top cover to reach the control board. Locate the onboard fuse (often a glass or ceramic fuse).
  • 4. Test/replace fuse: With a multimeter, check continuity of the fuse. If blown, replace with the same rating. If it blows again immediately, there is a short that must be diagnosed by a technician.
  • 5. Check for visible board damage: Burn marks or bulging components indicate a failed main control board, which should be replaced.
  • 6. If board and fuse are good: The keypad or power button circuit may be faulty; replacing the user interface board may be required.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements