Possible Causes
Blown internal fuse on main PCB, Faulty power cord or plug, Failed main control board, Defective power switch or keypad
How to Fix / Troubleshooting
Safety: Ensure the outlet is safe and not overloaded. Unplug the unit before opening any covers.
Steps to troubleshoot no power:
- 1. Check outlet and breaker: Test the outlet with another appliance. Reset any tripped breakers.
- 2. Inspect power cord: Look for cuts, burns, or kinks. If damaged, replace the power cord assembly.
- 3. Access main PCB: Remove the rear or top cover to reach the control board. Locate the onboard fuse (often a glass or ceramic fuse).
- 4. Test/replace fuse: With a multimeter, check continuity of the fuse. If blown, replace with the same rating. If it blows again immediately, there is a short that must be diagnosed by a technician.
- 5. Check for visible board damage: Burn marks or bulging components indicate a failed main control board, which should be replaced.
- 6. If board and fuse are good: The keypad or power button circuit may be faulty; replacing the user interface board may be required.