Control Logic / Relay Failure
Dehumidifier powers on but compressor and fan never start; only display works
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty main control board relays, Incorrect humidity setpoint or mode, Defective humidity sensor reading 0% or 100%, Safety interlock (bucket, tilt) not engaged
How to Fix / Troubleshooting
Safety: Unplug before accessing internal components.
Steps to diagnose:
- 1. Verify settings: Ensure the unit is in dehumidify mode and the set humidity is lower than the current room humidity.
- 2. Check bucket and tilt switches: Confirm the water bucket is fully seated and the unit is level. A misaligned bucket or tilt sensor can prevent operation.
- 3. Observe display humidity: If it shows 0% or 99–100% constantly, the humidity sensor may be faulty and preventing start.
- 4. Listen for relay clicks: When calling for dehumidification, you should hear relays click on the main PCB. If not, the board may be defective.
- 5. Replace faulty parts: Replace the humidity sensor module if readings are clearly wrong. If sensor is good but relays do not energize, replace the main control board.