Ariston
Excessive Vibration / Imbalance
Dehumidifier vibrates excessively and may move on the floor during operation
Advertisements
Possible Causes
Unit not level, Fan blade out of balance, Loose compressor mounts, Internal components touching cabinet
How to Fix / Troubleshooting
Safety: Unplug before adjusting or opening the unit.
Steps to reduce vibration:
- 1. Level the unit: Place the dehumidifier on a flat, solid surface. Adjust feet if available or use shims to eliminate rocking.
- 2. Check fan blade: Inspect for bent or missing sections. Replace the fan blade if damaged.
- 3. Inspect compressor mounts: Ensure rubber mounts are not cracked or missing. Replace worn compressor mounting grommets.
- 4. Check for contact points: Look for wiring or tubing touching the cabinet and secure them with clips or foam to prevent rattling.
Advertisements
Repair Difficulty
Easy
2/5