E5
Ariston Compressor Overload / Overcurrent Protection

Dehumidifier shows E5 and will not start or stops shortly after starting

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor start relay or PTC, Shorted compressor winding, Low mains voltage or unstable power supply, Faulty main control board power stage

How to Fix / Troubleshooting

Safety: Unplug the unit and wait several minutes before accessing internal components. Capacitors on the control board may hold charge.

Steps to troubleshoot E5:

  • 1. Verify power supply: Plug the dehumidifier directly into a wall outlet (no extension cords). Ensure the outlet provides the correct voltage and is not shared with heavy loads.
  • 2. Listen for compressor start attempts: When powered on, you may hear a click from the relay/PTC and a brief hum from the compressor before E5 appears. Repeated clicking without running suggests a start component issue.
  • 3. Access the compressor compartment: Remove the rear or side panel to expose the compressor and its start components (relay/PTC and overload protector).
  • 4. Inspect the PTC/relay: Disconnect power. Remove the plastic cover on the compressor terminals. Check the PTC/relay for burn marks, cracks, or melted plastic. If damaged, replace with the correct Ariston compressor start relay/PTC specified for your model.
  • 5. Check wiring: Ensure all spade connectors are tight on the compressor terminals and overload protector.
  • 6. Advanced testing (optional): With a multimeter, measure compressor winding resistances. Very low or zero resistance between any two pins may indicate a shorted compressor, which typically requires full compressor replacement.
  • 7. If start components are good: The main control board’s power stage (relay or triac) may be faulty. Replacement of the main control board is recommended and should be done by a professional.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Compressor Start Relay/PTC
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements