F0
Ariston Water Level Sensor / Float Switch Fault (Humidifier Mode)

Humidifier function (on combo units) shows F0 and stops adding moisture; fan may still run

Advertisements

Possible Causes

Stuck or misaligned float, Dirty water tank or float chamber, Failed reed switch or level sensor, Damaged wiring to level sensor

How to Fix / Troubleshooting

Safety: Turn off and unplug the unit before removing the water tank.

Steps to address F0:

  • 1. Remove and empty the tank: Take out the humidifier water tank and empty any remaining water. Rinse to remove debris.
  • 2. Inspect the float: Inside the tank or base, locate the plastic float that rises with water level. Ensure it moves freely up and down and is not jammed by scale or dirt.
  • 3. Clean the float chamber: Use a soft brush and mild vinegar solution to remove mineral deposits. Rinse thoroughly and dry.
  • 4. Check the level sensor: Many Ariston units use a reed switch in the base. Inspect for corrosion or broken wires. Ensure the magnet in the float is intact.
  • 5. Reassemble and test: Refit the tank correctly, ensuring it seats fully. Power on and check if F0 clears.
  • 6. If F0 persists: The water level sensor/reed switch may be defective and require replacement. Access usually involves removing the base cover; take care not to damage seals.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Level Sensor / Float Switch
Check Price on Amazon