Possible Causes

Drifted humidity sensor, Sensor contaminated by dust or chemicals, Incorrect sensor type fitted, Control board calibration fault

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing the sensor or control board.

Steps to address H1:

  • 1. Verify environment: Use an external hygrometer to compare room humidity with the unit’s display. Large discrepancies suggest sensor issues.
  • 2. Clean the humidity sensor: Access the sensor behind the intake grille. Gently blow away dust with compressed air. Avoid liquids.
  • 3. Check sensor part number: If the sensor was previously replaced, confirm it matches the original Ariston specification.
  • 4. Replace sensor if readings are inaccurate: Install a new humidity sensor module and retest.
  • 5. If H1 persists with a new sensor: The control board calibration or ADC circuit may be faulty, requiring main control board replacement.