P2
Ariston Continuous Drain / Pump Protection Fault

Dehumidifier shows P2 and stops; continuous drain hose may be attached

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked drain hose, Kinked or elevated hose causing backflow, Internal drain channel clogged, Failed condensate pump (on pump-equipped models)

How to Fix / Troubleshooting

Safety: Unplug the unit before handling hoses or opening panels. Water may spill; protect flooring.

Steps to address P2:

  • 1. Check hose routing: Ensure the drain hose slopes downward continuously to the drain point and is not kinked or looped.
  • 2. Clear blockages: Disconnect the hose and flush it with water to remove sludge or scale. Use a flexible brush if needed.
  • 3. Inspect internal drain outlet: Where the hose connects to the dehumidifier, check for debris or mold blocking the outlet. Clean with a small brush.
  • 4. For pump models: If your Ariston unit has an internal pump, listen for pump operation when water should be draining. If silent or just humming, the condensate pump may be jammed or failed.
  • 5. Access pump (if equipped): Remove the rear or side panel to reach the pump. Check for obstructions in the pump inlet and outlet. Clean as needed.
  • 6. Replace pump if defective: If the pump does not run when powered and not blocked, replace the pump assembly with the correct Ariston part.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condensate Pump Assembly
Check Price on Amazon