Possible Causes
Cracked humidifier tank, Misfitted tank cap or gasket, Overfilling beyond max line, Internal hose or seal leak in humidifier module
How to Fix / Troubleshooting
Safety: Unplug the unit and clean up spilled water.
Steps:
- 1. Inspect tank: Remove and fill the humidifier tank over a sink to check for leaks. Replace the humidifier water tank if cracked.
- 2. Check cap and gasket: Ensure the cap is tight and the gasket is not damaged or missing.
- 3. Do not overfill: Fill only to the indicated maximum level.
- 4. Internal leaks: If water appears from inside the cabinet, the internal humidifier hoses or seals may be leaking. This requires disassembly and replacement of the humidifier module seals/hoses by a technician.