Ariston Reduced Mist Output

Humidifier mode produces very little or no mist even though the tank is full and no error is shown

Advertisements

Possible Causes

Mineral scale on ultrasonic transducer, Low water level at transducer, Blocked mist outlet, Weak ultrasonic driver circuit

How to Fix / Troubleshooting

Safety: Unplug and remove the water tank before servicing.

Steps to restore mist:

  • 1. Clean transducer: Gently clean the ultrasonic disc with a cotton swab and white vinegar to remove scale. Rinse and dry.
  • 2. Check water level: Ensure the tank design allows proper water flow to the transducer chamber and that any valves open correctly when the tank is seated.
  • 3. Clear mist outlet: Inspect and clean the mist outlet channel and any directional nozzles.
  • 4. If output remains weak: The ultrasonic mist generator module or driver circuit may be failing and should be replaced.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ultrasonic Mist Generator Module
Check Price on Amazon

We may earn a commission from links on this page.