Beko Overheating Component / Electrical Overload

Dehumidifier emits a burning smell or hot plastic odor

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dust buildup on coils and fan, Failing fan motor, Overheating PCB component, Loose electrical connection causing arcing

How to Fix / Troubleshooting

Safety: Immediately unplug the unit. Do not continue to operate it until the cause is identified. Risk of fire.

Steps:

  • 1. Visual inspection: Remove covers and look for discolored plastic, burnt wiring, or scorched PCB areas.
  • 2. Clean thoroughly: Remove dust from coils, fan, and PCB using a vacuum and soft brush.
  • 3. Check fan operation: Ensure the fan runs at full speed. A slow or stalled fan can cause overheating.
  • 4. Inspect wiring connections: Tighten any loose spade connectors and check for melted insulation.
  • 5. Replace burnt components: If any component or wiring is visibly burnt, replace the affected part or the entire PCB. If damage is extensive, consult a professional.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Fan Motor or Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements