Possible Causes
Stuck float, Misaligned tank, Faulty tank level switch, Magnet in float weakened or displaced
How to Fix / Troubleshooting
Safety: Unplug before inspecting the tank area.
Steps:
- 1. Remove and clean tank: Wash the tank and float mechanism to remove slime or mineral deposits.
- 2. Check float movement: Ensure the float moves freely and returns to the down position when the tank is empty.
- 3. Inspect tank seating: Make sure the tank slides fully into place and presses any internal levers or switches.
- 4. Test level switch: Access the float switch or reed switch assembly and test for correct operation with a multimeter. Replace if faulty.