Possible Causes

Stuck float, Misaligned tank, Faulty tank level switch, Magnet in float weakened or displaced

How to Fix / Troubleshooting

Safety: Unplug before inspecting the tank area.

Steps:

  • 1. Remove and clean tank: Wash the tank and float mechanism to remove slime or mineral deposits.
  • 2. Check float movement: Ensure the float moves freely and returns to the down position when the tank is empty.
  • 3. Inspect tank seating: Make sure the tank slides fully into place and presses any internal levers or switches.
  • 4. Test level switch: Access the float switch or reed switch assembly and test for correct operation with a multimeter. Replace if faulty.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Level Float Switch Assembly