E6
Beko
Compressor Overload or Start Protection Fault
Dehumidifier displays E6 and compressor does not run
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Overheated compressor, Faulty compressor overload protector, Defective PTC start device, Low mains voltage or wiring issue, Internal compressor failure
How to Fix / Troubleshooting
Safety: Unplug the unit. Compressor terminals carry mains voltage; only work on them if you are competent with electrical safety.
Steps:
- 1. Allow cool‑down: If the unit has been running continuously, leave it unplugged for at least 45–60 minutes to let the compressor cool. Then reconnect and test.
- 2. Check ventilation and cleanliness: Ensure condenser coil and rear grille are clean and not blocked. Poor airflow can cause compressor overheating.
- 3. Access compressor compartment: Remove the rear or side panel to expose the compressor. Locate the overload protector and PTC start relay attached to the compressor terminals.
- 4. Inspect components: Look for signs of burning, cracking, or melted plastic on the overload and PTC. Ensure they are firmly seated on the compressor pins.
- 5. Electrical checks (advanced): With power disconnected, remove the overload and PTC. Test the overload for continuity; it should be closed at room temperature. A permanently open overload must be replaced. The PTC should show a moderate resistance (not 0 Ω or infinite).
- 6. Replace faulty start components: If the overload or PTC is defective, replace with Beko‑specified parts for your model. Refit them securely on the compressor terminals.
- 7. If E6 persists and compressor hums or does not start: The compressor itself may be seized or internally damaged. This requires sealed‑system service and usually professional replacement.