Beurer
Mechanical Vibration or Fan Noise
Beurer humidifier makes loud buzzing or rattling noises during operation.
Advertisements
Possible Causes
Loose fan blades or mounting screws, Debris caught in fan, Unit placed on uneven or resonant surface, Worn fan motor bearings
How to Fix / Troubleshooting
Safety: Unplug the unit before opening the housing.
Steps:
- Check placement: Place the humidifier on a solid, level surface. Avoid hollow furniture that can amplify vibration.
- Inspect external parts: Ensure the water tank and covers are properly seated and not vibrating.
- Access the fan: Remove the housing to expose the fan. Look for dust, hair, or foreign objects on the blades.
- Clean the fan: Use a soft brush and vacuum to remove debris. Hold the fan blades while cleaning to avoid spinning them with the vacuum.
- Tighten screws: Check and tighten any loose fan mounting screws or brackets.
- Check bearings: Spin the fan by hand. If it feels rough or wobbly, the motor bearings may be worn and the fan motor should be replaced.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Fan Motor Assembly