Beurer
Reduced Ultrasonic Output Due to Scaling
Beurer humidifier produces very weak mist output compared to normal.
Advertisements
Possible Causes
Heavy limescale on ultrasonic transducer, Mineral buildup in water chamber, Use of hard tap water without demineralization filter
How to Fix / Troubleshooting
Safety: Unplug the unit and remove the water tank.
Cleaning procedure:
- Empty and rinse: Pour out any remaining water from the base and tank.
- Descale transducer and chamber: Fill the base water chamber with a 1:1 mixture of white vinegar and warm water until the transducer is submerged. Let soak for 30–45 minutes.
- Gently clean: Use a soft cloth or cotton swab to wipe away loosened scale from the transducer and chamber walls. Do not use metal tools or abrasive pads.
- Rinse thoroughly: Rinse the chamber several times with clean water to remove all vinegar residue.
- Replace filters: If your Beurer model uses an anti-limescale or water softening filter cartridge, replace it according to the manual.
- Use better water: To prevent recurrence, use demineralized or distilled water, especially in hard water areas.
Advertisements
Repair Difficulty
Very Easy
1/5
Required Part
Ultrasonic Transducer Assembly
Check Price on Amazon