Beurer Ultrasonic Transducer Failure

Beurer ultrasonic humidifier runs but produces no mist at all.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed piezoelectric transducer disc, Loose or corroded transducer wiring, Burned transducer driver circuit on PCB

How to Fix / Troubleshooting

Safety: Unplug the humidifier and empty the water tank before inspection.

Checks:

  • Confirm basic operation: Ensure the unit is powered on, fan is running, and water tank is full and correctly seated.
  • Inspect the transducer area: Remove the tank and look at the metal disc at the bottom of the water chamber. Check for cracks, discoloration, or heavy limescale.
  • Descale the transducer: Apply a small amount of vinegar-water solution to the disc and let sit for 10–15 minutes. Gently wipe with a soft cloth. Do not scratch the surface.
  • Test again: Refill the tank and test. If there is still no mist and you cannot feel vibration when touching the plastic near the disc (with the unit on and water present), the transducer or driver is likely faulty.
  • Replace transducer (advanced): Remove the base cover, disconnect the transducer wires from the PCB, and unscrew the transducer assembly. Install a compatible Beurer ultrasonic transducer kit, ensuring the gasket is properly seated to prevent leaks.

If replacing the transducer does not restore mist, the driver circuit on the main PCB may be defective and should be serviced professionally.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Ultrasonic Transducer Assembly
Check Price on Amazon

We may earn a commission from links on this page.