E9
Beurer Compressor or Refrigeration System Protection Fault

Beurer dehumidifier displays E9 and will not start the compressor.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Overcurrent detected in compressor circuit, Failed compressor start relay or PTC, High-pressure switch open due to blocked airflow, Faulty main control board

How to Fix / Troubleshooting

Safety: Unplug the unit. Compressor circuits carry mains voltage and can store charge.

Basic checks:

  • Ensure proper ventilation: Keep at least 20–30 cm clearance around the unit. Blocked airflow can cause high pressure and trigger protection.
  • Clean filters and coils: Remove and wash the air filter. Vacuum dust from the condenser and evaporator coils.
  • Power reset: After cleaning, leave the unit unplugged for 30 minutes to allow internal pressures to equalize, then restart.

Advanced checks (technician recommended):

  • Inspect compressor terminals: Remove the side panel and check the compressor start device (relay/PTC). Look for burn marks or melted plastic.
  • Test start device: Replace the compressor start relay/PTC if it shows signs of overheating or rattles when shaken.
  • Check wiring: Ensure all compressor and fan connectors are secure.

Important: If E9 persists, the compressor or sealed system may be faulty. Sealed system work (refrigerant, brazing) must only be done by a licensed refrigeration technician.