Bionaire Fan Motor Failure

Dehumidifier fan does not run; compressor may start and then shut off

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Burned-out fan motor, Seized fan bearings, Obstructed fan blade, Faulty fan relay or triac on control PCB

How to Fix / Troubleshooting

Safety: Unplug the unit before working near the fan or motor.

Steps:

  • Check for obstructions: Remove the front/rear cover and inspect the fan blade for debris or objects preventing rotation. Clear any obstructions.
  • Spin test: Gently spin the fan blade by hand. If it is stiff, noisy, or does not coast freely, the motor bearings are likely failing and the motor should be replaced.
  • Voltage test (advanced): With the unit carefully powered and controls calling for fan operation, measure voltage at the fan motor terminals. If rated voltage is present but the motor does not run, replace the fan motor assembly.
  • Control board: If no voltage is supplied to a good motor, the fan control circuit on the main PCB is likely defective and the board should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Fan Motor Assembly
Check Price on Amazon

We may earn a commission from links on this page.