E7
Bionaire
Defrost System / Coil Temperature Error
Dehumidifier beeps and shows E7; fan may still run but no dehumidification
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective defrost sensor, Sensor not making good contact with evaporator, Control board defrost algorithm failure, Severely restricted airflow causing abnormal coil temperature
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing internal components.
Steps:
- Clean filter and grilles: Ensure the air filter is clean and the intake/exhaust are unobstructed to prevent abnormal coil temperatures.
- Inspect defrost sensor: The defrost sensor is usually the same as or in addition to the evaporator NTC, clipped to the coil. Confirm it is firmly attached and not dangling.
- Check wiring: Follow the sensor wires back to the PCB and reseat the connector. Look for damage or corrosion.
- Test sensor: Measure resistance at room temperature and compare to expected NTC values. Replace if open/shorted or out of range.
- Board replacement: If a new sensor and proper airflow do not clear E7, the main control PCB’s defrost circuit may be faulty and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Defrost Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.