HI
Bionaire
High Humidity or Humidity Sensor Out of Range
Dehumidifier display shows HI and may run continuously
Advertisements
Possible Causes
Actual humidity above sensor range, Failed humidity sensor reading maximum value, Sensor contaminated with dust or moisture, Control board humidity circuit fault
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing internal components.
Steps:
- Verify environment: Use a separate hygrometer to confirm actual room humidity. In very damp spaces, HI may be normal and the unit will run continuously.
- Clean sensor: Access the humidity sensor near the intake or on the control panel. Gently clean with dry air or a soft brush to remove dust.
- Dry sensor: If the sensor has been directly exposed to water, allow it to dry completely before retesting.
- Replace sensor: If HI is displayed even in a dry room, replace the humidity sensor module.
- Control board: If a new sensor does not correct the reading, replace the main control PCB.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Humidity Sensor Module
Check Price on Amazon