HI
Bionaire High Humidity or Humidity Sensor Out of Range

Dehumidifier display shows HI and may run continuously

Advertisements

Possible Causes

Actual humidity above sensor range, Failed humidity sensor reading maximum value, Sensor contaminated with dust or moisture, Control board humidity circuit fault

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing internal components.

Steps:

  • Verify environment: Use a separate hygrometer to confirm actual room humidity. In very damp spaces, HI may be normal and the unit will run continuously.
  • Clean sensor: Access the humidity sensor near the intake or on the control panel. Gently clean with dry air or a soft brush to remove dust.
  • Dry sensor: If the sensor has been directly exposed to water, allow it to dry completely before retesting.
  • Replace sensor: If HI is displayed even in a dry room, replace the humidity sensor module.
  • Control board: If a new sensor does not correct the reading, replace the main control PCB.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Humidity Sensor Module
Check Price on Amazon