P2
Black+Decker
Bucket Full / Water Tank Full Protection
Dehumidifier shows P2 and stops, bucket is full or nearly full
Advertisements
Possible Causes
Water bucket full, Bucket not seated correctly, Faulty bucket full switch or float, Misaligned bucket causing switch not to reset
How to Fix / Troubleshooting
Safety: Unplug the unit before removing the bucket to avoid spills near live parts.
Steps to clear P2:
- Empty the bucket: Carefully slide out the water bucket and empty it completely. Rinse to remove any slime or debris.
- Check bucket placement: Reinsert the bucket firmly until it is flush with the front of the unit. Ensure it is not tilted or misaligned.
- Inspect the float: Inside the bucket, verify that the float moves freely and is not stuck in the up (full) position. Clean any buildup that may cause sticking.
- Check the bucket switch: Behind the bucket, locate the bucket full switch. Confirm that the bucket or float actuator properly presses the switch when installed.
- Replace faulty parts: If P2 remains even with an empty, correctly seated bucket, replace the bucket float or bucket full switch assembly as required.
Advertisements
Repair Difficulty
Very Easy
1/5
Required Part
Bucket Full Switch
Check Price on Amazon