Black+Decker Bucket Full Protection Failure

Water overflows from the bucket even though the unit should shut off when full

Advertisements

Possible Causes

Stuck or broken bucket float, Faulty bucket full switch, Float magnet missing (on magnetic sensors), Switch wiring shorted

How to Fix / Troubleshooting

Safety: Unplug the unit and mop up any spilled water before servicing.

Steps:

  • Inspect float mechanism: Remove the bucket and locate the float. Ensure it is intact and moves freely. Replace if broken.
  • Check magnet (if used): Some floats use a magnet to trigger a reed switch. Ensure the magnet is still attached to the float.
  • Test bucket full switch: With a multimeter, test the switch for proper operation as the float moves. Replace the bucket full switch if it does not change state.
  • Inspect wiring: Ensure the switch wires are not shorted together, which would prevent the unit from sensing a full bucket.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Bucket Full Switch
Check Price on Amazon

We may earn a commission from links on this page.